TSYNC - Certificate of Volatility
Certificate of Volatility for Spectracom TSync PCIe Bus-level Timing Boards
Tuesday, April 5, 2011
Certificate of Volatility | ||||||||
Model: Spectracom TSync-PCIe bus-level timing boards |
Part Numbers: 1191-1001-0600 (Has no on-board GPS receiver) 1191-2001-0600 (has on-board GPS receiver) |
Manufacturer: Spectracom Corporation | ||||||
Street Address: 95 Methodist Hill Drive | ||||||||
City: Rochester | State: NY | Zip: 14623 | ||||||
Volatile Memory |
||||||||
Does the item contain volatile memory (i.e., memory whose contents are lost when power is removed)? X Yes No |
||||||||
If the answer is ‘Yes’, please provide the following information for each type (use additional sheets if required): | ||||||||
Type (SRAM, DRAM, etc.): SRAM |
Size: 64KB |
User Modifiable: Yes No |
Function: System memory: Contains system stack |
Process to Sanitize: Remove power |
||||
Type (SRAM, DRAM, etc.): SDRAM |
8MB | User Modifiable: Yes No |
Function: System memory: Contains executing code and system heap |
Process to Sanitize: Remove power |
||||
Non-Volatile Memory |
||||||||
Does the item contain non-volatile memory (i.e., memory whose contents are retained when power is removed)? Yes No |
||||||||
If the answer is ‘Yes’, please provide the following information for each type (use additional sheets if required): | ||||||||
Type (BBRAM, Flash, EEPROM, etc.): Flash |
Size: 8MB |
User Modifiable: Yes No |
Function: Contains the run-time, default firmware and FPGA images; this memory is utilized during to store new images during normal operation. |
Process to Sanitize: None |
||||
Type (BBRAM, Flash, EEPROM, etc.): Flash |
Size: 512KB | User Modifiable: Yes No |
Function: Contains the boot loader firmware and a compressed FPGA image, this is not accessible during normal operation. |
Process to Sanitize: None |
||||
Type (BBRAM, Flash, EEPROM, etc.): EEPROM |
Size: 8KB |
User Modifiable: Yes No |
Function: System memory- Contains product configuration data, which write the following during normal operation:
|
Process to Sanitize: The user reference table can be reset to the factory default or overwritten by the user |
||||
Media |
||||||||
Does the item contain media storage capability (i.e., removable or non-removable disk drives, tape drives, memory cards, etc.)? Yes No |
||||||||
Additional Information: The TSync-PCIe (Model 1191-2001-0600) product contains an on-board Trimble Resolution-T GPS receiver module which may have its own volatile/non-volatile memory. Please refer to Trimble (http://www.trimble.com/timing) for details regarding memories used on this module. The Spectracom TSync-PCIe board does not direct the GPS module to store any persistent information (including position). Removing power from the TSync-PCIe board should sanitize any information held in volatile or battery-backed memories on this module. |
||||||||
Vendor Representative Information | ||||||||
Name: Keith Wing |
Title: Tech Support Manager |
Office Phone: (585) 321-5823 |
Fax/Email: (585) 321-5219 techsupport@spectracomcorp.com |
|||||